Clean operating room air conditioning system solution
Clean surgical air conditioning system
According to the clean operating room design specifications, the clean air conditioning system must have core technical indicators such as constant temperature, constant humidity, fresh air treatment, air purification, and ensuring the positive and negative pressure difference in the controlled area to achieve the design requirements for controlling the concentration of bacteria and reducing the risk of infection. Clean air conditioners have multiple functions such as air purification, transportation, cooling, dehumidification, humidification, heating, heat recovery, and intelligent control, providing users with clean environment system solutions suitable for different purification levels and different working conditions.
Clean operating room air conditioning system solution Ⅰ
DC frequency conversion outdoor unit + clean operating room air conditioning unit + PLC intelligent control
1、Frequency conversion technology: The DC frequency conversion compressor is used to adjust the operating frequency of the compressor according to the temperature change, which is efficient and energy-saving
2、Low ambient temperature cooling: The outdoor unit adopts EC fan, and the speed of the outdoor fan is controlled by the condensing pressure sensor to achieve -20℃ low temperature cooling operation;
3、Low temperature air supply: Shenglin's unique technology, through the grading and separate control of the evaporator, reduces the evaporation temperature, and the minimum air supply temperature is 5℃;
4、Precise temperature control: electric reheating and electric preheating are steplessly adjusted by SCR to accurately control the indoor temperature
5、Low ring temperature heating: advanced air jet enthalpy technology, normal heating operation at an ambient temperature of -20°C.
Air conditioning system solution for clean operating room Ⅱ
Four-pipe air-cooled heat pump heat recovery unit + clean operating room combined air conditioner + PLC control
Multi-function: four-pipe, frequency conversion adjustment, cooling and heating operation can realize energy recovery at the same time, no need to add a hot water tank to adjust the water capacity on the hot water side;
Low-temperature heating: Adopting jet enthalpy and high-temperature liquid injection technology, heating operation at minus 20℃, and energy efficiency ratio higher than 2.1;
Low temperature refrigeration: EC fan is used to detect the discharge pressure of the compressor to achieve normal refrigeration at -20°C,
Cooling and heating balance: automatic cooling and heating balance under partial cooling and heating load, automatic distribution of refrigerant flow;
System stability: Adopting single four-valve design, consistent operation, mature system technology, stable and reliable operation;
Energy saving and environmental protection: annual heat recovery can be realized, energy recovery can be adjusted, cooling energy efficiency ratio ≥ 4.0, while heat energy efficiency ratio ≥ 5.0, combined cooling and heating energy efficiency ratio ≥ 9.0, operation energy saving effect is more significant ;
Intelligent control: Microcomputer PLC control technology, automatically detects the operating status, and realizes energy-saving operation;
Fault self-check: automatic fault detection system can detect operation faults such as suction and exhaust pressure, exhaust temperature, phase loss and reverse phase, overcurrent and overload;
Unique technology: the perfect combination of single four-way valve design, ultra-low temperature heating design, low temperature refrigeration design, and stable mode conversion.
Clean operating room air conditioning system solution Ⅲ
Air-cooled heat pump + clean operating room combined air conditioning unit + PLC control
Precise temperature control: DC inverter compressor is used, and the operating power of the compressor is self-matched according to changes in ambient temperature;
Low ambient temperature refrigeration: The outdoor unit adopts EC fan, and the speed of the outdoor fan is controlled by the condensing pressure sensor to achieve -20℃ low temperature cooling operation;
Low ring temperature heating: advanced air jet enthalpy technology, normal heating operation at an ambient temperature of -20℃;
Intelligent defrosting: super-cooling ice suppression technology, combined with Sunlin’s unique defrosting module, with frost defrosting, frost-free heating
Smart cloud service: PC client + mobile App real-time monitoring.
- 01 Feb,2024Dry Cooler D4-8x910 In Stock Is On Sale! Discount!
- 06 Sep,2023Pad Adiabatic Dry Cooler Trial Operation Before Shipment
- 06 Sep,2023828kW Adiabatic Cooling System Dry Cooler Loading
- 17 Aug,2022Flat Type Dry Cooler Finished For Canada Client
- 06 Sep,20231061kW dry cooler loading for USA client
- 31 Mar,2021Peru client Install Shenglin Adiabatic Dry Cooler At Site