Air Cooler

Air Cooler
Product features 1 . Air Cooler 2. simple structure,accurate and reliable operating system 3. Certificates:CE,RoHS,ISO9001:2000 4. energy-efficient,environmentally friendly. 5. medium and low temperature cooling equipment. 6. integral installation,anticollision,rainproof structure feature 7. hermeti...
We're here to help
Easy ways to get the answers you need.
Contact Now
Contact Now
- TEL:0086-21-35324169
- FAX:0086-21-35324166
- Email:sales@shenglintec.com
Product features
1 . Air Cooler
2. simple structure,accurate and reliable operating system
2. simple structure,accurate and reliable operating system
3. Certificates:CE,RoHS,ISO9001:2000
4. energy-efficient,environmentally friendly.
5. medium and low temperature cooling equipment.
6. integral installation,anticollision,rainproof structure feature
7. hermetic design and anti-corrosion outer shell
8 . low noise, efficient , strong-wind fan motor ,avoidance of sunshine and raining effect
9. completely welded to ensure less leakage (below 3g/year)
10. smaller volume,easy installation

Main Technical Parameters of DD-type Low Noise High
Efficiency Air Coolers
Main Technical Parameters of DJ-type Low Noise High Efficiency Air Coolers
Efficiency Air Coolers
Type |
Refrigerating Capacity |
Cooling Area (mm) |
Pitch of Fins (mm) |
Air cooler | Electric pipe | ||||||||
Qty. | Dia | Wind Rate |
Wind Pressure |
Power |
Voltage Water Flow |
KW×pcs |
Water drain (kw) |
Voltage Water Flow |
|||||
DD-1.4/7 | 1400(1200) | 8.4 | 6 | 1 | φ300 | 1700 | 140 | 80 | 380 | 0.5×2 | 0.5 | 380 | |
DD-2.35/12 | 2350(2000) | 11.5 | 6 | 2 | φ300 | 2×1700 | 140 | 2×80 | 380 | 0.9×2 | 0.9 | 380 | |
DD-3.0/15 | 3000(2600) | 15.2 | 6 | 2 | φ300 | 2×1700 | 140 | 2×80 | 380 | 0.9×2 | 0.9 | 380 | |
DD-4.0/22 | 4000(3450) | 22.8 | 6 | 2 | φ350 | 2×3200 | 90 | 2×120 | 380 | 1.2×2 | 1.2 | 380 | |
DD-6.0/30 | 6000(5150) | 31.7 | 6 | 2 | φ350 | 2×3200 | 90 | 2×200 | 380 | 1.5×2 | 1.5 | 380 | |
DD-8.0/40 | 8000(6900) | 43.4 | 6 | 2 | φ400 | 2×4800 | 120 | 2×250 | 380 | 1.6×2 | 1.6 | 380 | |
DD-12.0/60 | 12000(10300) | 59.0 | 6 | 2 | φ400 | 2×4800 | 120 | 2×250 | 380 | 1.8×2 | 1.8 | 380 | |
DD-16.0/80 | 16000(13750) | 87.8 | 6 | 2 | φ450 | 2×6600 | 160 | 2×550 | 380 | 1.6×5 | 1.6 | 380 | |
DD-20.0/100 | 20000(17200) | 106.7 | 6 | 3 | φ450 | 3×6600 | 160 | 3×550 | 380 | 1.8×5 | 1.8 | 380 | |
DD-24.0/120 | 24000(20650) | 131.5 | 6 | 3 | φ450 | 3×6600 | 160 | 3×550 | 380 | 2.4×5 | 2.4 | 380 | |
DD-28.0/140 | 28000(24100) | 153.5 | 6 | 4 | φ450 | 4×6600 | 160 | 4×550 | 380 | 3×5 | 3.0 | 380 | |
DD-32.1/160 | 32100(27600) | 175 | 6 | 4 | φ500 | 4×9900 | 170 | 4×740 | 380 | 3.2×5 | 3.2 | 380 | |
DD-37.4/200 | 37400(32200) | 208 | 6 | 2 | φ600 | 2×10000 | 200 | 2×1100 | 380 | 2.7×8 | 2.7 | 380 | |
DD-46.8/250 | 46800(40300) | 259 | 6 | 3 | φ600 | 3×10000 | 200 | 3×1100 | 380 | 3.3×8 | 3.3 | 380 | |
DD-56.2/310 | 56200(48300) | 310.5 | 6 | 3 | φ600 | 3×12000 | 200 | 3×2200 | 380 | 3.5×8 | 3.5 | 380 |
Main Technical Parameters of DJ-type Low Noise High Efficiency Air Coolers
Type |
Refrigerating Capacity |
Cooling Area (mm) |
Pitch of Fins (mm) |
Air cooler | Electric pipe | ||||||||
Qty. | Dia | Wind Rate |
Wind Pressure |
Power |
Voltage Water Flow |
KW×pcs |
Water drain (kw) |
Voltage Water Flow |
|||||
DJ-13.2/8 | 1320(1150) | 7.95 | 9 | 2 | φ300 | 2×1700 | 140 | 2×80 | 380 | 0.9×2 | 0.9 | 380 | |
DJ-2.3/15 | 2300(2000) | 15.9 | 9 | 2 | φ350 | 2×3200 | 90 | 2×120 | 380 | 1.2×2 | 1.2 | 380 | |
DJ-4.0/20 | 4000(3450) | 21.8 | 9 | 2 | φ350 | 2×3200 | 90 | 2×200 | 380 | 1.5×2 | 1.5 | 380 | |
DJ-5.1/30 | 5100(4400) | 30 | 9 | 2 | φ400 | 2×4800 | 120 | 2×250 | 380 | 1.6×2 | 1.6 | 380 | |
DJ-7.8/40 | 7800(6700) | 40.2 | 9 | 2 | φ400 | 2×4800 | 120 | 2×250 | 380 | 1.8×2 | 1.8 | 380 | |
DJ-9.8/55 | 9800(8400) | 60.3 | 9 | 2 | φ450 | 2×6600 | 160 | 2×550 | 380 | 1.6×5 | 1.6 | 380 | |
DJ-12.8/70 | 12800(11000) | 73.3 | 9 | 3 | φ450 | 3×6600 | 160 | 3×550 | 380 | 1.8×5 | 1.8 | 380 | |
DJ-15.7/85 | 15700(13500) | 90.4 | 9 | 3 | φ450 | 3×6600 | 160 | 3×550 | 380 | 2.4×5 | 2.4 | 380 | |
DJ-18.8/100 | 18800(16160) | 105.3 | 9 | 4 | φ450 | 4×6600 | 160 | 4×550 | 380 | 3×5 | 3.0 | 380 | |
DJ-21.6/115 | 21600(18600) | 120.6 | 9 | 4 | φ500 | 4×9900 | 170 | 4×740 | 380 | 3.2×5 | 3.2 | 380 | |
DJ-29.3/140 | 23900(26600) | 142.7 | 9 | 2 | φ600 | 2×10000 | 420 | 2×1100 | 380 | 2.7×8 | 2.7 | 380 | |
DJ-29.0/170 | 29000(24900) | 178 | 9 | 3 | φ600 | 3×10000 | 420 | 3×1100 | 380 | 3.3×8 | 3.3 | 380 | |
DJ-35.9/210 | 35900(30900) | 209 | 9 | 3 | φ600 | 3×12000 | 420 | 3×2200 | 380 | 3.5×8 | 3.5 | 380 |
Water-melt-frost system is generally used in the large capacity cold air machine.
It is simple and reliable, has good effect in frost melting, less warehouse temperature rise in frost melting process, especially suitable for fast freezing refrigerating warehouse.
The disadvantage of this water-melt-frost system is that the water used to melt frost should not lower than 15℃,
so this kind of air cooler can’t be adopted by the area of low atmosphere temperature.
Various water-melt-frost air coolers are provided for selection.
It is simple and reliable, has good effect in frost melting, less warehouse temperature rise in frost melting process, especially suitable for fast freezing refrigerating warehouse.
The disadvantage of this water-melt-frost system is that the water used to melt frost should not lower than 15℃,
so this kind of air cooler can’t be adopted by the area of low atmosphere temperature.
Various water-melt-frost air coolers are provided for selection.
Get Price And Support
Please leave your telephone number or mobile phone nubmer for emergency contact, in case we can not reach you by mail.
Previous:none
Related Product
+Newsmore
- 27 Feb,2014SGS certificate
- 27 Feb,2014BV certificate
- 10 Jan,2014Welcome Mr Chen to Visit Shenglin
- 14 Jan,2014Cooperated with big refrigerator factory in Sweden
- 21 Jan,2015CE Certification for Heat Pump
- 30 Jan,2015Thanks for John`s Visting
- 30 Jan,2015Air handing units finished for Iraq Client
- 13 Feb,2015North Korea inspect our precision air conditioner.