Air cooled coil are designed to work in even the most hostile conditions, whether at high temperatures, high pressures,
or where the environment is highly corrosive.Our cooler tubes can be produced in materials such as stainless steel
as well as copper and copper alloys, to best suit the environment.
Specification
Tube sizes range from 7mm to 15.88mm. Materials include copper, aluminum, stainless steel, and others. This product is brazed or welded depending on the material and application.
or where the environment is highly corrosive.Our cooler tubes can be produced in materials such as stainless steel
as well as copper and copper alloys, to best suit the environment.
Specification
Tube sizes range from 7mm to 15.88mm. Materials include copper, aluminum, stainless steel, and others. This product is brazed or welded depending on the material and application.
Item
|
Cooling coil Type
|
Operation medium
|
Operation pressure (MPa)
|
Application
|
1 | Φ16/Φ9.52/Φ12.7 Copper tube with aluminium fin | Cold/hot water | ≤1.6 | Used for combined air handling unit, fan coil etc air conditioning devices |
2 | Φ18/Φ20 Steel pipe winding with steel sheet | Steam | ≤0.2 | Used for combined air handling unit, fan coil etc air conditioning devices |
3 | Φ16/Φ9.52/Φ12.7 Copper tube with aluminium fin | Brine | ≤1.6 | Used for heat transfer in cold storage and all kinds of low temperature systems |
4 | Φ9.52/Φ7.94/Φ7 Copper tube with aluminium fin | Ethylene glycol | ≤1.6 | Used of energy recovery and low temperature system devices |
5 | Φ16 Copper tube with aluminium fin | Ice mud | ≤1.6 | Used for dry operation condition, fresh air dehumidification etc systems |
6 | Φ9.52/Φ7.94/Φ7 Copper tube with aluminium fin | R22 | ≤1.9 | Used for industry and commerce air conditioning system |
7 | Φ9.52/Φ7.94/Φ7 Copper tube with aluminium fin | R407C | ≤1.9 | Used for industry and commerce air conditioning system |
8 | Φ9.52/Φ7.94/Φ7 Copper tube with aluminium fin | R134a | ≤3.1 |
Used for vehicle and vessel etc transportation devices |
Mold of Copper tube&aluminum fin/copper fin
Mold of Stainless steel tube&aluminum fin/copper fin
Fin Pattern | Copper Tube O.D.(mm) | Row Space(mm) | Hole Space(mm) |
Fin Thickness(mm) |
Fin Space(mm) | ||||
Flat fin | Sine wave with blade fin | Smooth sine wave fin | Window fin | Sesamoid fin | |||||
A | 7 | 12.7 | 21 | 0.105 | / | / | 1.3 | 1.3 | / |
B | 7 | 13.2 | 17.6 | 0.105 | / | / | 1.3 | 1.3 | / |
C | 7 | 12.7 | 20.4 | 0.105 | / | / | 1.3~1.8 | 1.3~1.8 | / |
D | 7 | 12.7 | 19.05 | 0.105 | / | / | 1.3~1.8 | 1.3~1.8 | / |
E | 7.94 | 15.88 | 25.4 | 0.105 | 1.8~3.0 | 1.8~3.0 | 1.8~3.0 | 1.8~3.0 | / |
E | 7.94 | 19.05 | 22 | 0.105~0.13 | 1.4~3.0 | 1.4~3.0 | 1.4~3.0 | 1.4~3.0 | / |
F | 9.52 | 22 | 25.4 | 0.105~0.15 | 1.6~3.2 | 1.6~3.2 | 1.6~3.2 | 1.6~3.2 | / |
G | 9.52 | 22 | 25.4 | 0.18~0.4 | 3.5~6.35 | / | / | / | / |
H | 9.52 | 21.65 | 25 | 0.105~0.18 | 1.6~3.2 | 1.6~3.2 | 1.6~3.2 | 1.6~3.2 | / |
I | 9.52 | 21.65 | 25 | 0.15~0.24 | 3.2~6.35 | 3.2~6.35 | 3.2~6.35 | / | / |
J | 12.75 | 27.5 | 31.75 |
0.115~0.15 |
1.5~3.5 | 1.5~3.5 | 1.5~3.5 | 1.5~3.5 | 1.6~3.2 |
K | 15.88 | 33 | 38.1 | 0.115~0.15 | 1.5~4.0 | 1.5~4.0 | 1.5~4.0 | / | / |
L | 15.88 | 34.64 | 40 | 0.115~0.15 | / | 2.6~3.5 | 2.6~3.5 | / | / |
Mold of Stainless steel tube&aluminum fin/copper fin
Fin Pattern | Stainless steel Tube O.D.(mm) | Row Space(mm) | Hole Space(mm) |
Fin Thickness(mm) |
Fin Space(mm) | ||||
Flat fin | Sine wave with blade fin | Smooth sine wave fin | Window fin | Sesamoid fin | |||||
A | 9.52 | 22 | 25.4 | 0.105~0.15 | 1.6~3.2 | 1.6~3.2 | 1.6~3.2 | 1.6~3.2 | / |
B | 9.52 | 16.5 | 19.05 | 0.105~0.115 | 1.4~2.5 | 1.4~2.5 | 1.4~2.5 | / | / |
C | 12.75 | 27.5 | 31.75 |
0.115~0.15 |
1.5~3.5 | 1.5~3.5 | 1.5~3.5 | 1.5~3.5 | 1.6~3.2 |
D | 15.88 | 33 | 38.1 | 0.115~0.15 | 1.5~4.0 | 1.5~4.0 | 1.5~4.0 | / |
/ |
2.Used for heat transfer in cold storage and all kinds of low temperature systems
3.Used of energy recovery and low temperature system devices
4.Used for dry operation condition, fresh air dehumidification etc systems
5.Used for industry and commerce air conditioning system
6.Used for vehicle and vessel etc transportation devices
Application:

Products show:



Previous:Heating Coils/Water Coil
Next:Fin Tube coil
+Newsmore
- 21 Jun,2018429kW dry cooler for Singapore wastewater treatment factory.
- 21 Jun,2018176Kw water cooled chillers finished for Malaysia factory
- 21 Jun,201852kw dry cooler finished for local client.
- 22 Nov,2017AHU cooling coils and centrifugal fan for Saudi Arabia client
- 22 Nov,2017Waiting loading container for South Africa client, air cooler
- 22 Nov,2017Fin type condenser finished for French client
- 22 Nov,20171580KW water cooled screw chiller finished.